| To Order Output Options add the option to the end of the part # (Ex: HBC-90HDA-2-M, HBC-690HDL-3-Z) |
| To Order Input Options: Change the HBC- prefix to LPC, TP, TPLP, or CTMB (Ex: LPC-90HDA, TP-690HDL) |
|
|
|
|
|
|
|
|
|
|
|
| Options |
25A / pole |
40A / pole |
50A / pole |
80A / pole |
100A |
| Add output option to end of part # |
S Series |
A Series |
L Series |
N Series |
G Series |
| |
|
AC |
DC |
AC |
DC |
AC |
DC |
AC |
DC |
AC |
DC |
| -2 |
3 Phase / 2 Pole configuration |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| -3 |
3 Phase / 3 Pole configuration |
X |
X |
X |
X |
X |
X |
|
|
X |
X |
| -10 |
Random turn-on |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| -WH |
Wiring harness for multi-pole configurations |
X |
X |
X |
X |
X |
X |
|
|
X |
X |
| -E |
24VAC Control |
X |
|
X |
|
X |
|
X |
|
X |
|
| -Z |
LED (input status indicator) |
|
X |
|
X |
|
X |
|
X |
|
X |
| -M |
MOV - External transient voltage suppression |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| -P |
Internal transient voltage suppression |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| -F |
Fast-on terminals (up to 50A total) |
X |
X |
X |
X |
X |
X |
X |
X |
|
|
| -4 |
400 MHZ operation |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| -TP |
Through panel-mount |
X |
X |
X |
X |
X |
X |
|
|
|
|
| -PM |
Panel Mount |
X |
X |
X |
X |
X |
X |
Std. |
Std. |
| -ND |
No Din Clip |
X |
X |
X |
X |
X |
X |
Std. |
Std. |
| -D |
DIN Mount |
Std. |
Std. |
Std. |
X |
X |
X |
X |
| -CT |
Current Transducer |
X |
X |
X |
X |
X |
X |
|
|
X |
X |
| |
|
|
|
|
|
|
|
|
|
|
|
| Input Options |
|
|
|
|
|
|
|
|
|
|
| Add input option to beginning of part # - in place of HBC |
| TP- |
Time proportioning controller (Burst Fire) |
|
X |
|
X |
|
X |
|
X |
|
X |
| TPLP- |
Loop powered time proportioning controller (Burst Fire) |
|
X |
|
X |
|
X |
|
X |
|
X |
| LPC- |
Linear phase angle controller |
|
X |
|
X |
|
X |
|
X |
|
X |
| CTMB- |
Control monitor board |
|
X |
|
X |
|
X |
|
|
|
X |
| MBxxx- |
Relay monitoring board |
|
X |
|
X |
|
X |
|
X |
|
X |
| |
|
|
|
|
|
|
|
|
|
|
|
| Options |
60A / pole |
40A / pole |
30A / pole |
100A / pole |
25A & 40A |
| Add option to end of part # |
K Series |
3 Phase K |
3 Phase K |
F Series |
Dual / Quad |
| |
|
|
2 Pole |
3 Pole |
|
|
Series |
| |
|
AC |
DC |
AC |
DC |
AC |
DC |
AC |
DC |
DC |
| -2 |
3 Phase / 2 Pole configuration |
X |
X |
Std. |
|
|
Selectable |
2, 4, 6, 8, or 12 pole configuration |
| -3 |
3 Phase / 3 Pole configuration |
|
|
|
|
Std. |
Selectable |
| -10 |
Random turn-on |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| -WH |
Wiring harness for multi-pole configurations |
X |
X |
|
|
|
|
X |
X |
X |
| -E |
24VAC Control |
X |
|
X |
|
|
|
X |
|
|
|
| -Z |
LED (input status indicator) |
|
X |
|
X |
Std. |
|
X |
|
|
| -M |
MOV - External transient voltage suppression |
X |
X |
X |
X |
Std. |
X |
X |
|
|
| -P |
Internal transient voltage suppression |
X |
X |
X |
X |
|
|
X |
X |
X |
| -F |
Fast-on terminals (up to 50A total) |
X |
X |
X |
X |
|
|
|
|
Std. |
| -4 |
400 MHZ operation |
X |
X |
X |
X |
|
|
X |
X |
|
|
| -TP |
Through panel-mount |
X |
X |
X |
X |
X |
X |
|
|
X |
| -PM |
Panel Mount |
X |
X |
X |
X |
X |
X |
Std. |
X |
| -ND |
No Din Clip |
X |
X |
X |
X |
X |
X |
Std. |
X |
| -D |
DIN Mount |
Std. |
Std. |
Std. |
X |
X |
Std. |
| -CT |
Current Transducer |
X |
X |
X |
X |
|
|
X |
X |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| Input Options |
|
|
|
|
|
|
|
|
|
|
| Add input option to beginning of part # - in place of HBC |
|
|
|
|
|
|
|
|
| TP- |
Time proportioning controller (Burst Fire) |
|
X |
|
|
|
|
|
X |
|
|
| TPLP- |
Loop powered time proportioning controller (Burst Fire) |
|
X |
|
X |
|
|
|
X |
|
|
| LPC- |
Linear phase angle controller |
|
X |
|
|
|
|
|
X |
|
|
| MBxxx- |
Relay Monitoring Board |
|
X |
|
X |
|
|
|
X |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| Options |
10A |
60A / pole |
70A / pole |
30A / pole |
|
|
| Add option to end of part # |
11 Series |
DC Series |
Strip Wire Series |
HK Series |
|
|
| |
|
AC |
DC |
Bipolar |
Mosfet |
AC |
DC |
AC |
DC |
|
|
| -2 |
3 Phase / 2 Pole configuration |
|
|
X |
X |
X |
X |
X |
X |
|
|
| -3 |
3 Phase / 3 Pole configuration |
|
|
X |
X |
X |
X |
X |
X |
|
|
| -10 |
Random turn-on |
Some Models |
|
|
X |
X |
X |
X |
|
|
| -E |
24VAC Control |
|
|
|
|
X |
|
X |
|
|
|
| -Z |
LED (input status indicator) |
Std. * |
|
|
Std. |
Std. |
|
|
| -M |
MOV - External transient voltage suppression |
Std. * |
|
|
X |
X |
X |
X |
|
|
| -P |
Internal transient voltage suppression |
|
|
|
|
X |
X |
X |
X |
|
|
| -P |
Removable/replaceable relay (HBC-11P-) |
X |
X |
|
|
|
|
|
|
|
|
| -TP |
Through panel-mount |
|
|
X |
X |
X |
X |
|
|
|
|
| -PM |
Panel Mount |
|
|
X |
X |
X |
X |
|
|
|
|
| -ND |
No Din Clip |
|
|
X |
X |
X |
X |
|
|
|
|
| -D |
DIN Mount |
Std. |
Std. |
Std. |
Std. |
|
|
| -CT |
Current Transducer |
|
|
|
|
X |
X |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| Input Options |
|
|
|
|
|
|
|
|
|
|
| Add option to beginning of part # |
|
|
|
|
|
|
|
|
|
|
| TP- |
Time proportioning controller (Burst Fire) |
|
|
X |
X |
|
|
|
|
|
|
| TPLP- |
Loop powered time proportioning controller (Burst Fire) |
|
|
X |
X |
|
|
|
|
|
|
| LPC- |
Linear phase angle controller |
|
|
X |
X |
|
|
|
|
|
|
| * Most Models |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|