Phase Angle Control to 25A - S Series LPC |
|
Features:
- Suitable for inductive loads
- True linear output phase angle control
- Line voltage compensation
- Selectable Soft Start
- Automatic 50/60Hz operation
- Adjustable voltage limit option Prefix (LPCVL)
- LED input status indiactor standard
- Selectable Input
- Relays approved to the following: UL,
CSA, VDE and CE
- Solid State Relay Assemblies rated to
25A/pole @ 40° C (100% duty cycle) |
| OUTPUT SPECIFICATIONS |
|
| |
LPC-25DS |
LPC-25HDS |
LPC-625HDS |
LPC-50DS |
LPC-50HDS |
LPC-650HDS |
| Operating Voltage (47-63 Hz) [Vrms] |
24-280 |
48-530 |
48-660 |
24-280 |
48-530 |
48-660 |
| Load Current Range [Arms] |
.04-15 |
.04-15 |
.04-15 |
.04-25 |
.04-25 |
.04-25 |
| Transient Overvoltage [Vpk] |
600 |
1200 |
1200 |
600 |
625 |
1200 |
| Max. Surge Current, (16.6ms) [Apk] |
250 |
250 |
250 |
625 |
625 |
625 |
| Max. On-State Voltage Drop [Vpk] |
1.6 |
1.7 |
1.7 |
1.6 |
1.7 |
1.7 |
| Max. Turn-on and Turn-off Time |
1/2 cycle |
1/2 cycle |
1/2 cycle |
1/2 cycle |
1/2 cycle |
1/2 cycle |
| Max.I²t for fusing (8.3mS) |
260 |
260 |
260 |
1620 |
1620 |
1620 |
| Max. Off-State Leakage Current [mArms] |
10 |
10 |
5 |
10 |
10 |
5 |
| Power Factor (Min.) with Max. Load |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
|
Input Specifications:
0-10VDC
0-5VDC
2-10VDC
1-5VDC
4-20mA
0-20mA
Potentiometer
0-135Ω (Change prefix to LPC35-)
Pulse Width Modulation (Change prefix to LPCPW-) |
| Note: 24 VAC Power Supply on same Phase as controller REQUIRED (see Accessories) |
|
|
Phase Angle Control to 40A - A Series LPC |
|
Features:
- Suitable for inductive loads
- True linear output phase angle control
- Line voltage compensation
- Selectable Soft Start
- Automatic 50/60Hz operation
- Adjustable voltage limit option Prefix (LPCVL)
- LED input status indiactor standard
- Selectable Input
- Relays approved to the following: UL,
CSA, VDE and CE
- Solid State Relay Assemblies rated to
40A/pole @ 40° C (100% duty cycle) |
| OUTPUT SPECIFICATIONS |
|
| |
LPC-25DA |
LPC-25HDA |
LPC-50DA |
LPC-50HDA |
LPC-90HDA |
LPC-690HDA |
| Operating Voltage (47-63 Hz) [Vrms] |
24-280 |
48-530 |
24-280 |
48-530 |
48-530 |
48-660 |
| Load Current Range [Arms] |
.04-20 |
.04-20 |
.04-30 |
.04-30 |
.04-40 |
.04-40 |
| Transient Overvoltage [Vpk] |
600 |
1200 |
600 |
1200 |
1200 |
1200 |
| Max. Surge Current, (16.6ms) (Apk) |
250 |
250 |
625 |
625 |
1200 |
1200 |
| Max. On-State Voltage Drop [Vpk] |
1.6 |
1.7 |
1.6 |
1.7 |
1.7 |
1.7 |
| Max. Turn-on and Turn-off Time |
1/2 cycle |
1/2 cycle |
1/2 cycle |
1/2 cycle |
1/2 cycle |
1/2 cycle |
| Max.I²t for fusing (8.3mS) |
260 |
260 |
1620 |
1620 |
6000 |
6000 |
| Max. Off-State Leakage Current [mArms] |
10 |
10 |
10 |
10 |
10 |
5 |
| Power Factor (Min.) with Max. Load |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
|
Input Specifications:
0-10VDC
0-5VDC
2-10VDC
1-5VDC
4-20mA
0-20mA
Potentiometer
0-135Ω (Change prefix to LPC35-)
Pulse Width Modulation (Change prefix to LPCPW-) |
| Note: 24 VAC Power Supply on same Phase as controller REQUIRED (see Accessories) |
|
|
Phase Angle Control to 50A - L Series LPC |
|
Features:
- Suitable for inductive loads
- True linear output phase angle control
- Line voltage compensation
- Selectable Soft Start
- Automatic 50/60Hz operation
- Adjustable voltage limit option Prefix (LPCVL)
- LED input status indiactor standard
- Selectable Input
- Relays approved to the following: UL,
CSA, VDE and CE
- Solid State Relay Assemblies rated to
50A/pole @ 40° C (100% duty cycle) |
| OUTPUT SPECIFICATIONS |
|
|
| |
TPLP-90HDL |
TPLP-690HDL |
| Operating Voltage (47-63 Hz) [Vrms] |
48-530 |
48-660 |
| Load Current Range [Arms] |
.04-50 |
.04-50 |
| Transient Overvoltage [Vpk] |
1200 |
1200 |
| Max. Surge Current, (16.6ms) [Apk] |
1200 |
1200 |
| Max. On-State Voltage Drop [Vpk] |
1.7 |
1.7 |
| Max. Turn-on Time |
1/2 cycle |
1/2 cycle |
| Max. Turn-off Time |
1/2 cycle |
1/2 cycle |
| Max.I²t for fusing (8.3mS) |
6000 |
6000 |
| Max. Off-State Leakage Current [mArms] |
10 |
5 |
| Power Factor (Min.) with Max. Load |
0.5 |
0.5 |
|
Input Specifications:
0-10VDC
0-5VDC
2-10VDC
1-5VDC
4-20mA
0-20mA
Potentiometer
0-135Ω (Change prefix to LPC35-)
Pulse Width Modulation (Change prefix to LPCPW-) |
| Note: 24 VAC Power Supply on same Phase as controller REQUIRED (see Accessories) |
|
|
Phase Angle Control to 70A - K Series LPC |
|
Features:
- Suitable for inductive loads
- True linear output phase angle control
- Line voltage compensation
- Selectable Soft Start
- Automatic 50/60Hz operation
- Adjustable voltage limit option Prefix (LPCVL)
- LED input status indiactor standard
- Selectable Input
- Relays approved to the following: UL,
CSA, VDE and CE
- Solid State Relay Assemblies rated to
70A/pole @ 40° C (100% duty cycle) |
| OUTPUT SPECIFICATIONS |
|
|
|
| |
LPC-90HDXK |
LPC-690HDXK |
LPC-125HDXK |
| Operating Voltage (47-63 Hz) [Vrms] |
48-530 |
48-660 |
48-530 |
| Load Current Range [Arms] |
.04-60 |
.04-60 |
.04-70 |
| Transient Overvoltage [Vpk] |
1200 |
1200 |
1200 |
| Max. Surge Current, (16.6ms) [Apk] |
1200 |
1200 |
1750 |
| Max. On-State Voltage Drop [Vpk] |
1.7 |
1.7 |
1.7 |
| Max. Turn-on Time |
1/2 cycle |
1/2 cycle |
10.0mS |
| Max. Turn-off Time |
1/2 cycle |
1/2 cycle |
40.0mS |
| Max.I²t for fusing (8.3mS) |
6000 |
6000 |
12,700 |
| Max. Off-State Leakage Current [mArms] |
10 |
5 |
10 |
| Power Factor (Min.) with Max. Load |
0.5 |
0.5 |
0.5 |
|
Input Specifications:
0-10VDC
0-5VDC
2-10VDC
1-5VDC
4-20mA
0-20mA
Potentiometer
0-135Ω (Change prefix to LPC35-)
Pulse Width Modulation (Change prefix to LPCPW-) |
| Note: 24 VAC Power Supply on same Phase as controller REQUIRED (see Accessories) |
|
|
Phase Angle Control to 80A - N Series LPC |
|
Features:
- Suitable for inductive loads
- True linear output phase angle control
- Line voltage compensation
- Selectable Soft Start
- Automatic 50/60Hz operation
- Adjustable voltage limit option Prefix (LPCVL)
- LED input status indiactor standard
- Selectable Input
- Relays approved to the following: UL,
CSA, VDE and CE
- Solid State Relay Assemblies rated to
80A/pole @ 40° C (100% duty cycle) |
| OUTPUT SPECIFICATIONS |
|
|
|
|
| |
LPC-50DN |
LPC-50HDN |
LPC-90HDN |
LPC-125HDN |
| Operating Voltage (47-63 Hz) [Vrms] |
24-280 |
48-530 |
48-530 |
48-530 |
| Load Current Range [Arms] |
.04-45 |
.04-45 |
.04-70 |
.04-80 |
| Transient Overvoltage [Vpk] |
600 |
1200 |
1200 |
1200 |
| Max. Surge Current, (16.6ms) [Apk] |
625 |
625 |
1200 |
1750 |
| Max. On-State Voltage Drop [Vpk] |
1.6 |
1.7 |
1.7 |
1.7 |
| Max. Turn-on Time |
1/2 cycle |
1/2 cycle |
1/2 cycle |
1/2 cycle |
| Max. Turn-off Time |
1/2 cycle |
1/2 cycle |
1/2 cycle |
1/2 cycle |
| Max.I²t for fusing (8.3mS) [A²sec] |
1620 |
1620 |
6000 |
12,700 |
| Max. Off-State Leakage Current [mArms] |
10 |
10 |
10 |
10 |
| Power Factor (Min.) with Max. Load |
0.5 |
0.5 |
0.5 |
0.5 |
|
Input Specifications:
0-10VDC
0-5VDC
2-10VDC
1-5VDC
4-20mA
0-20mA
Potentiometer
0-135Ω (Change prefix to LPC35-)
Pulse Width Modulation (Change prefix to LPCPW-) |
| Note: 24 VAC Power Supply on same Phase as controller REQUIRED (see Accessories) |
|
|
Phase Angle Control to 100A - F Series LPC |
|
Features:
- Suitable for inductive loads
- True linear output phase angle control
- Line voltage compensation
- Selectable Soft Start
- Automatic 50/60Hz operation
- Adjustable voltage limit option Prefix (LPCVL)
- LED input status indiactor standard
- Selectable Input
- Relays approved to the following: UL,
CSA, VDE and CE
- Solid State Relay Assemblies rated to
100A/pole @ 40° C (100% duty cycle) |
| OUTPUT SPECIFICATIONS |
|
| |
LPC-90DF3 |
LPC-690DF3 |
LPC-125DF3 |
| |
|
| FAN OPTION (Add letter of Fan to end of above part #) |
B-120VAC Fan |
C - 240VAC Fan |
I - 24VDC Fan |
| (EX: LPC-125DF3B - Denotes 3 Phase, 3 Pole, w/120VAC Fan) |
| |
|
|
|
| Operating Voltage (47-63 Hz) |
48-530 |
48-660 |
48-530 |
| Load Current Range [Arms] |
.04-90 |
.04-50 |
.100-100 |
| Transient Overvoltage [Vpk] |
1200 |
1200 |
1200 |
| Max. Surge Current, (16.6ms) [Apk] |
1200 |
1200 |
1750 |
| Max. On-State Voltage Drop [Vpk] |
1.7 |
1.7 |
1.7 |
| Max. Turn-on Time |
1/2 cycle |
1/2 cycle |
1/2 cycle |
| Max. Turn-off Time |
1/2 cycle |
1/2 cycle |
1/2 cycle |
| Max.I²t for fusing (8.3mS) |
6000 |
6000 |
12700 |
| Max. Off-State Leakage Current [mArms] |
10 |
5 |
10 |
| Power Factor (Min.) with Max. Load |
0.5 |
0.5 |
0.5 |
|
Input Specifications:
0-10VDC
0-5VDC
2-10VDC
1-5VDC
4-20mA
0-20mA
Potentiometer
0-135Ω (Change prefix to LPC35-)
Pulse Width Modulation (Change prefix to LPCPW-) |
| Note: 24 VAC Power Supply on same Phase as controller REQUIRED (see Accessories) |
|
|